The Caloritech™ WXL Process Duct Heater is designed for installation in process ducts to heat air or other non-hazardous gases. It features a steel mounting plate, terminal box and stainless steel element support plate. The heater is inserted into a duct through a hole and secured with suitable bolts, studs or screws.
Please note that all process duct heater installations must include a device such as a thermocouple control or proximity high limit cutout to limit the outlet temperature in the event of fan failure or malfunction of the process temperature regulator.
Features & Benefits At A Glance
- replaceable "W" shaped incoloy® elements, each rated at 2 kW
- Suitable for top, bottom or side mounting installations
- Multiple circuits are selected to limit the line current in each circuit to 48 amps
- Suitable for outlet air temperatures up to 425°C (797°F), provided air velocity requirements are met; modified heaters with lower watt densities for lower air velocities are available on custom order
- Available as standard in a watt density of 27 W/in.2
- Available in a range of standard wattages, from 6 kW to 84 kW
- Available in a range of standard voltages, from 208V to 600V
- cCSAus approved; GOST approved for global markets