Aviation Coalescer Filter 3l Filters™ Engineered Products 3l Filters™ Fuel Gas Conditioning CCI Thermal Technologies Inc. partners with RACOR
catadyneruffneckcaloritech3lfiltersnorsemandriquik

HIF & HIFO Series Coreless Element

3L Filters™ HIF/HIFO Series Coreless ElementCatalog Pages Warranty & Liability, Warranty and Fire Sheet

HIF and HIF0 industrial coreless high efficiency elements are designed to remove solids from jet fuels, diesel fuels, gasoline, kerosene and aviation gas. They are also used for solid removal from industrial lubricating, hydraulic and insulating oils.

HIF coreless high efficiency elements offer superior contaminant loading and eliminate filter element pleat blinding. Pleat blinding blocks effective contaminate loading of filter pleats, shortens element life and increases filter change outs.

Features & Benefits at a Glance

  • offer 30% more contaminate holding capacity than comparable standard pleated elements
  • crushable filter element has no metal components
  • crushable element reduces disposal volume by up to 85%
  • designed to fit competitor's coreless center tubes
  • incinerable, consult local regulations
  • high flow rate, low initial pressure drop
  • collapse pressure of 75 psid
  • pH range 5 to 9
  • maximum operating temperature of 240°F (115°C)
  • out to in flow direction
  • standard glass-filled nylon end caps eliminate corrosion and offer excellent thermal stability
  • standard Viton® gaskets
    *Viton® is a registered trademark of DuPont™
  • recommended cartridge change out 15 psid
  • available in micron ratings of 1, 5, 10, and 25
You are here: 3L Filters HIF & HIFO Series Coreless Element